acc. to HD 21.5 S3 or DIN VDE 0245 part 202
Temperature range:
Temperature range (3000 hrs): –20 °C to +80 °C
Temperature at continuous load acc. to HD: +60 °C (8025/8013) or +70 °C 7572
Recommended application:
7-wire strand construction is particularly suited for insulation displacement connectors.
Construction / Materials:
Conductor: Finely stranded respectively stranded rigid copper conductor, bare or tinned, according to DIN VDE 0295, conductor category 5 (8025) and conductor category 2 (8013/7572)
Insulation: PVC compound with characteristics TI 2 according to HD 21.1
Sheath: PVC compound with characteristics TM2 according
to HD 21.1
Nominal voltage: 300/300 V Uo/U
Use according to VDE certificate of conformity:
S03VV-F (8025): For internal wiring and protected installation inside appliances, partly external use for fixed installation,
but not as cord sets.
S03VV-R (8013): For internal wiring and protected
installation inside appliances, partly external use for fixed installation
without mechanical load.
S03VV-F (7572): For protected installation inside appliances.